The variable frequency motor can effectively solve the heat dissipation problem at low revs and the noise problem at high revs. It can be widely used in the fields like petroleum, chemical, wind turbine, water pump, compressor, heating and refrigerating applications where speed regulation and frequent starting is needed.
main Technincal Parameter:
adjust speed radge: 5Hz~100Hz ( or 6Hz~120Hz) ( 1: 20 ) for 50Hz( or 60Hz )power supply. the motor running at 5Hz~50Hz ( or6Hz~60Hz ) torq constant. at 50Hz~100Hz ( or 60Hz~120Hz ) constantoutput.ref to fig1, fig2, when use inverter power supply. at low freq case,the start torq / rate torq≥1.25, thetechnical parameter ref to tab 1.
Power(kw) | level 2 | level 4 | level 6 | level 8 | ||||||||
cabin seat no | Standard current(A) | Rated torque(N.m) | cabin seat no | Standard current(A) | Rated torque(N.m) | cabin seat no | Standard current(A) | Rated torque(N.m) | cabin seat no | Standard current(A) | Rated torque(N.m) | |
0.12 | / | / | / | 63M1 | 0.44 | 0.76 | / | / | / | / | / | / |
0.18 | 63M1 | 0.53 | 0.58 | 63M2 | 0.62 | 1.15 | 71M1 | 0.8 | 1.91 | 80M1 | 0.9 | 2.49 |
0.25 | 63M2 | 0.69 | 0.80 | 71M1 | 0.79 | 1.59 | 71M2 | 0.9 | 2.65 | 80M2 | 1.2 | 3.46 |
0.37 | 71M1 | 0.69 | 1.18 | 71M2 | 1.12 | 2.38 | 80M1 | 1.3 | 3.9 | 90S | 1.5 | 5.12 |
0.55 | 71M2 | 1.4 | 1.75 | 80M1 | 1.6 | 3.5 | 80M2 | 1.8 | 5.84 | 90L | 2.2 | 7.6 |
0.75 | 80M1 | 1.9 | 2.4 | 80M2 | 2.1 | 4.7 | 90S | 2.5 | 7 | 100L1 | 2.4 | 10.2 |
1.1 | 80M2 | 2.6 | 3.5 | 90S | 2.7 | 7 | 90L | 3.5 | 10.5 | 100L2 | 3.3 | 15 |
1.5 | 90S | 3.4 | 4.7 | 90L | 3.7 | 9.5 | 100L | 4.5 | 14 | 112M | 4.4 | 24.4 |
2.2 | 90L | 4.7 | 7 | 100L1 | 5 | 14 | 112M | 6.1 | 21 | 132S | 6.4 | 28 |
3 | 100L | 6.4 | 9.5 | 100L2 | 6.8 | 19.1 | 132S | 7.9 | 28.5 | 132M | 6.5 | 38 |
4 | 112M | 8.2 | 12.7 | 112M | 8.8 | 25.4 | 132S1 | 10.2 | 37 | 160S1 | 10.8 | 50 |
5.5 | 132S1 | 11.1 | 17.5 | 132S1 | 11.6 | 35 | 132S2 | 13.7 | 52.5 | 160S2 | 14.5 | 70.5 |
7.5 | 132S2 | 15 | 23.8 | 132S2 | 15.4 | 47.7 | 160M | 18.6 | 71 | 160M | 19.4 | 95 |
As a famous China Variable Frequency Motor Manufacturers and Variable Frequency Motor company,Haoxin has an annual production capacity of 100,000 sets of drivers and wholesale Variable Frequency Motor Online,AC motors are usually divided into AC generators, AC motors and synchronous cameras according to their functions. Due to the reversibility of the working state of the motor, the same motor can be used as both a generator and a motor. With the development of power electronics technology, microelectronics technology, digital control technology and control theory, the dynamic and static characteristics of the AC drive system can be completely Comparing with DC drive system, AC drive system has been widely used, and the replacement of DC drive by AC drive has gradually become a reality.